Start with the temperature inside
A cold soak describes a period in which a battery exchanges heat with colder surroundings. It is not a guarantee that every cell has reached the same temperature. Large packs, sheltered compartments and recently operated equipment can retain heat unevenly. Record ambient temperature, several representative cell or module temperatures, rest time and recent current history. Without that context, two tests labelled “winter performance” may describe very different starting conditions.
In many lithium-ion cells, lower temperature slows ion transport through the electrolyte and active materials and changes the rates of electrode reactions. The resulting polarisation increases the difference between equilibrium voltage and terminal voltage under load. An equivalent resistance can help describe a particular test, but it is not a fixed material constant. Its apparent value changes with pulse duration, state of charge, temperature, cell design and the measurement method.
Power loss is not the same as lost inventory
When a load demands current, terminal voltage can fall to the battery-management system’s lower cutoff sooner than it would under warmer conditions. The delivered ampere-hours and watt-hours then decline, even though electrochemically stored charge remains. A lighter load or an approved warming step may make some of that energy accessible. Do not defeat the cutoff to recover it: the limit protects cells whose individual condition may be worse than the pack average.
Separate a reversible operating limitation from lasting degradation. A capacity check after controlled warming can help distinguish them, provided the comparison uses equivalent charge preparation, rest periods and discharge conditions. One low-temperature test cannot establish long-term ageing. Repeated cold operation, inappropriate charging, calendar ageing and mechanical damage may overlap. A credible report states the conditioning sequence and uncertainty instead of attributing every missing watt-hour to a single mechanism.
| Condition | During discharge | During charge |
|---|---|---|
| Cold transport | Greater voltage loss can restrict usable power and energy. | Slower insertion kinetics can restrict acceptable current. |
| Useful observation | Minimum cell voltage under the intended load. | Cell temperature, state of charge and the validated charge map. |
| Control response | Limit demand or condition the pack. | Reduce, delay or inhibit charging as specified. |